Three-phase separator sizing
Gas, oil or condensate, and water: vertical and horizontal vessels from the same input data, compared side by side. The gas section uses Souders–Brown with pressure correction, as in the two-phase calculator; liquid–liquid separation uses Stokes droplet settling and retention time. The horizontal vessel has an overflow weir or a water boot. Diameters are rounded up to the GOST 9617-76 standard series.
Sizing result
—Vertical or horizontal
| Parameter | Vertical | Horizontal |
|---|
Velocities and minimum diameter
| Criterion | K, m/s | v | Dmin, mm | DGOST |
|---|
Horizontal vessel diameter options
| D, mm | Vg/Vallow | Lgas, m | Lret, m | Lsettle, m | LT–T, m | L/D | Status |
|---|
Checks
| Parameter | Calculated | Limit | Note | Status |
|---|
Properties, geometry and nozzles
Calculation method
Gas section. The allowable gas velocity is found by the Souders–Brown method, with the K factor corrected for pressure and mist eliminator type, as in the two-phase calculator. The density difference is taken against the oil, the lighter liquid, which is conservative.
Liquid–liquid separation. The settling velocity of a water droplet in oil and the rising velocity of an oil droplet in water follow Stokes' law with the viscosity of the continuous phase. Layer volumes follow the set oil and water retention times.
Vertical vessel. The diameter is the largest of three: by gas, by oil rising against settling water droplets, and by water descending against rising oil droplets. The height adds up the water and oil layers, the inlet nozzle zone, the separation zone up to the mist eliminator and the zone above it.
Horizontal vessel. With an overflow weir, the settling section length is the largest of five: by droplet trajectory in the gas, by oil and water retention time, by water droplets settling through the oil layer and by oil droplets rising through the water layer; an oil chamber follows the weir. With a water boot, water collects in the boot, sized so that the water descends more slowly than the oil droplets rise.
Checks. Nozzle loading by ρv², velocity in the oil and water nozzles, margin to mist eliminator flooding, layer thicknesses, retention times, length or height to diameter ratio, pressure drop estimate.
Rating an existing vessel. For a given diameter and length (height) the calculator finds the gas load, maximum gas flow, oil and water retention times and the droplets that settle. Actual nozzles, mist eliminator diameter and the interface and liquid levels can be entered; volumes are then calculated from them, including the heads.
Heads and gas density. Heads are 2:1 elliptical or hemispherical, and the top of a vertical vessel can be a flat cover. Gas density can be taken from the process data sheet. Near the critical point the calculation does not run without it, because the correlations are unreliable there.
Limits of applicability. The result is a first approximation of vessel dimensions for a technical proposal. The retention time method assumes uniform flow across the section. Stable emulsions, viscous oil, wax and sand require heating, a demulsifier or coalescing elements, which the calculator does not size. It does not replace a strength calculation or a fluid dynamics analysis of the internals.
Method and standards: GPSA Engineering Data Book, API 12J, GOST 9617-76, GOST 2939-63.
Need a check beyond the standard method, such as a CFD analysis of the vessel with the actual inlet device? Let's discuss your task.