Gas separator sizing
Two-phase gas–liquid system, vertical and horizontal vessels from the same input data, compared side by side. Sizing by Souders–Brown with pressure correction, direct droplet settling and droplet trajectory in a horizontal vessel; nozzle check by ρv² and mist eliminator flooding check. Diameters are rounded up to the GOST 9617-76 standard series.
Sizing result
—Vertical or horizontal
| Parameter | Vertical | Horizontal |
|---|
Allowable gas velocity
| Method | K, m/s | Vallow, m/s | Dmin, mm | DGOST |
|---|
Horizontal vessel diameter options
| D, mm | Vg/Vallow | Ltraj, m | Lret, m | LT–T, m | L/D | Status |
|---|
Checks
| Parameter | Calculated | Limit | Note | Status |
|---|
Geometry and nozzles
Levels and liquid hold-up
| Level | Elevation, mm | Volume, m³ |
|---|
| Interval | Height, mm | Volume, m³ | Time, min |
|---|
Calculation method
Diameter. The allowable gas velocity is found by the Souders–Brown method, with the K factor corrected for pressure and mist eliminator type. The diameter is rounded up to the nearest standard size.
Height and length. A vertical vessel is laid out by zones: the liquid section with the liquid hold-up, the inlet nozzle zone, the separation zone up to the mist eliminator and the zone above it. The length of a horizontal vessel is the larger of two: by droplet trajectory in the gas space and by liquid hold-up.
Fluid properties. Gas density and viscosity are calculated from composition or specific gravity, accounting for compressibility and acid gas components. Liquid density is given at operating or standard conditions.
Checks. Nozzle loading by ρv², velocity in the liquid nozzle, margin to mist eliminator flooding, height or length to diameter ratio, pressure drop estimate. In rating mode the calculator finds the gas load, maximum gas flow and liquid hold-up of an existing vessel; actual nozzles, mist eliminator diameter and level elevations can be entered.
Heads and gas density. Heads are 2:1 elliptical or hemispherical, and the top of a vertical vessel can be a flat cover. Gas density can be taken from the process data sheet. Near the critical point the calculation does not run without it, because the correlations are unreliable there.
Limits of applicability. The result is a first approximation of vessel dimensions for a technical proposal. It does not replace a strength calculation, a fluid dynamics analysis of the internals or a slug flow check. Agree the coefficients with the internals supplier before issuing documentation.
Method and standards: GPSA Engineering Data Book, API 12J, GOST 9617-76, GOST 2939-63.
Need a check beyond the standard method, such as a CFD analysis of the vessel with the actual inlet device? Let's discuss your task.